Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur Arch Otorhinolaryngol ; 273(5): 1079-93, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-25613297

RESUMO

The UEMS Otorhinolaryngology-Head and Neck Surgery section is a dedicated body formed to promote the standardisation and harmonisation of European Otorhinolaryngology (ORL). The European Examination Board of Otorhinolaryngology and Head and Neck Surgery was created to establish a supranational final exam and accreditation for ORL Surgeons. It is open to candidates both from the European Union and outside the EU. The exam is composed of a written examination to assess mainly the theoretical knowledge of Otorhinolaryngological diseases. The second part, a viva voce examination, is designed to test the clinical application of knowledge based on case scenarios and clinical conditions presented to the candidates. The inaugural examination written component took place in Mannheim/Germany in 2009 and the inaugural Viva Voce examination in Vienna/Austria in 2010. Up to and including the year 2013, 858 participants have attempted one of the two exam components. Of the 858 participants, 305 were successful in both examinations and obtained the accreditation of the European Diploma (European Board Certification). The historical origins, development of the examination, its formal arrangements and the format of the examination are presented in this article.


Assuntos
Certificação , Avaliação Educacional , Otolaringologia , Europa (Continente) , União Europeia , Humanos
3.
Acta Otolaryngol ; 125(5): 481-91, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-16092537

RESUMO

CONCLUSIONS: Hearing may be conserved in adults after implantation with the Nucleus Contour Advance perimodiolar electrode array. The degree of hearing preservation and the maximum insertion depth of the electrode array can vary considerably despite a defined surgical protocol. Residual hearing combined with electrical stimulation in the same ear can provide additional benefits even for conventional candidates for cochlear implantation. OBJECTIVES: We present preliminary results from a prospective multicentre study investigating the conservation of residual hearing after implantation with a standard-length Nucleus Contour Advance perimodiolar electrode array and the benefits of combined electrical and acoustic stimulation. MATERIAL AND METHODS: The subjects were 12 adult candidates for cochlear implantation recruited according to national selection criteria. A "soft" surgery protocol was defined, as follows: 1-1.2-mm cochleostomy hole anterior and inferior to the round window; Nucleus Contour Advance electrode array inserted using the "Advance-off-stylet" technique; and insertion depth controlled by means of three square marker ribs left outside the cochleostomy hole. These procedures had been shown to reduce insertion forces in temporal bone preparations. Variations in surgical techniques were monitored using a questionnaire. Pure-tone thresholds were measured pre- and postoperatively. Patients who still retained thresholds <90 dB HL for frequencies up to 500 Hz were re-fitted with an in-the-ear (ITE) hearing aid. Word recognition was tested in quiet and sentence perception in noise for the cochlear implant alone and in combination with an ipsilateral hearing aid. RESULTS: Hearing threshold level data were available for 12 patients recruited from 6 of the centres. Median increases in hearing threshold levels were 23, 27 and 33 dB for the frequencies 125, 250 and 500 Hz, respectively. These median increases include the data for two patients who had total loss of residual hearing due to difficulties encountered during surgery. "Cochlear view" X-ray images indicated that the depth of insertion varied between 300 and 430 degrees, despite modest variations in the length of the electrode inserted (17-19 mm). The insertion angle had some influence on the preservation of residual hearing at frequencies of 250-500 Hz. Six of the 12 patients retained sufficient hearing for effective use of an ipsilateral ITE hearing aid (< or = 80 dB HL at 125 and 250 Hz; < or = 90 dB HL at 500 Hz). Word recognition scores in quiet were improved from 10% to 30% with the cochlear implant plus ipsilateral hearing aid in 3 patients who had at least 3 months postoperative experience. Signal:noise ratio thresholds for sentence recognition were improved by up to 3 dB. Patients reported that they experienced greatly improved sound quality and preferred to use the two devices together.


Assuntos
Implante Coclear , Surdez/diagnóstico , Surdez/cirurgia , Adulto , Idoso , Audiometria de Tons Puros , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Ajuste de Prótese , Índice de Gravidade de Doença , Percepção da Fala , Teste do Limiar de Recepção da Fala , Inquéritos e Questionários , Resultado do Tratamento , Membrana Timpânica/cirurgia
5.
Otolaryngol Head Neck Surg ; 129(5): 508-17, 2003 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-14595273

RESUMO

OBJECTIVE: Cerebrospinal fluid (CSF) fistulas need to be reliably diagnosed for the optimal management. Recently, in preference to beta2-transferrin, another CSF protein, beta-trace protein (betaTP), is similarly used with a new method for CSF diagnosis. This study evaluates the sensitive interpretation and limits of this new betaTP test for use in routine CSF fistula diagnosis. METHODS: Nephelometric detection of betaTP has been made in nasal secretion, serum, and CSF samples from healthy individuals as well as patients with reduced glomerular filtration rate and with bacterial meningitis. Additionally, 53 patients with suspected CSF rhinorrhea are also analyzed. RESULTS: The betaTP test can also be used to reliably diagnose CSF rhinorrhea even slightly better than the beta2-transferrin test. It should not be used for patients with renal insufficiency and bacterial meningitis as they substantially increase serum and decrease CSF betaTP values, respectively. CONCLUSION: Quantitative measurement of betaTP is a noninvasive, highly sensitive, quick, and inexpensive method that can be used for the detection of CSF rhinorrhea in nasal secretions. However, in cases where there is doubt about the interpretation, the results should be proved with beta2-transferrin test or sodium-fluorescein test.


Assuntos
Rinorreia de Líquido Cefalorraquidiano/diagnóstico , Oxirredutases Intramoleculares/imunologia , Nefelometria e Turbidimetria/instrumentação , Adolescente , Adulto , Anticorpos/imunologia , Rinorreia de Líquido Cefalorraquidiano/etiologia , Rinorreia de Líquido Cefalorraquidiano/imunologia , Creatinina/sangue , Diagnóstico Diferencial , Erros de Diagnóstico/prevenção & controle , Feminino , Taxa de Filtração Glomerular/fisiologia , Guias como Assunto , Humanos , Oxirredutases Intramoleculares/sangue , Oxirredutases Intramoleculares/líquido cefalorraquidiano , Lipocalinas , Masculino , Pessoa de Meia-Idade , Mucosa Nasal/imunologia , Mucosa Nasal/metabolismo , Poliestirenos/imunologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Base do Crânio/diagnóstico por imagem , Fraturas Cranianas/complicações , Fraturas Cranianas/diagnóstico por imagem , Tomografia Computadorizada por Raios X
6.
Hum Mutat ; 22(2): 180, 2003 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12872268

RESUMO

Recently, a 342-kb deletion involving GJB6 was associated with autosomal-recessive non-syndromic hearing loss (NSHL) and in combination with a GJB2 mutation with digenic NSHL. This deletion was the second most common mutation causing prelingual NSHL in Spain, and was frequently observed in patients from France and Israel. We screened 393 patients with NSHL being negative or heterozygous for GJB2 mutations for this GJB6 deletion using a multiplex PCR. Most patients were of Austrian (84.2%), and the other patients were of Turkish, Serbian, and Bosnian origin. None of these patients was carrying the deletion in GJB6 indicating that the occurrence of this deletion is restricted to certain populations.


Assuntos
Conexinas/genética , Perda Auditiva Neurossensorial/genética , Deleção de Sequência/genética , Áustria/epidemiologia , Áustria/etnologia , Bósnia e Herzegóvina/etnologia , Conexina 26 , Conexina 30 , DNA/genética , Genes Recessivos/genética , Testes Genéticos/métodos , Perda Auditiva Neurossensorial/etnologia , Humanos , Proteínas do Tecido Nervoso/genética , Síndrome , Turquia/etnologia , Iugoslávia/etnologia
7.
Artigo em Inglês | MEDLINE | ID: mdl-12824730

RESUMO

Auditory performance of cochlear implant (CI) children was assessed with the Listening Progress Profile (LiP) and the Monosyllabic-Trochee-Polysyllabic-Word Test (MTP) following the EARS protocol. Additionally, the 'initial drop' phenomenon, a recently reported decrease of auditory performance occurring immediately after first fitting, was investigated. Patients were 140 prelingually deafened children from various clinics and centers worldwide implanted with a MEDEL COMBI 40/40+. Analysis of LiP data showed a significant increase after 1 month of CI use compared to preoperative scores (p < 0.01). No initial decrease was observed with this test. Analysis of MTP data revealed a significant improvement of word recognition after 6 months (p < 0.01), with a significant temporary decrease after initial fitting (p < 0.01). With both tests, children's auditory skills improved up to 2 years. Amount of improvement was negatively correlated with age at implantation.


Assuntos
Percepção Auditiva , Implantes Cocleares , Surdez/reabilitação , Surdez/cirurgia , Adolescente , Fatores Etários , Criança , Pré-Escolar , Implante Coclear , Surdez/fisiopatologia , Feminino , Seguimentos , Testes Auditivos/métodos , Humanos , Lactente , Desenvolvimento da Linguagem , Testes de Linguagem/normas , Masculino , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...